Documentation:
Magnetron M1555 rednaznachen S-Band radar system, the frequency range 3040 ~ 3060MGts fixed. Maximum power output is 30 kW. For an input power greater than 25 watts, the heater voltage to be reduced to 3 seconds.
Magnetron M1555 ensures safe handling and operation. The product quality is constantly monitored by the manufacturer. The magnetrons are subject to mandatory testing for compliance with quality standards.
Specifications:
  • Maximum anode current - 12 A
  • Maximum input power anode - 100 kW
  • Pulse Duration: 1.0 ms
  • The rate of increase of the voltage pulse - 85 ° kV / microsecond
  • anode temperature - 120 °C
  • Heater Voltage: 6.3 V

 