Highlander HLD-B2
Voyage data recorder, or 'black box' Highlander HLD-S2 is a simplified version of VDR Highlander HLD-B2 - S-VDR (S-VDR). During the voyage Highlander HLD-S2 writes the data coming from radio navigation devices and CCTV cameras.
Simplified voyage data recorder (S-VDR), as determined by the requirements of the IMO Performance Standard MSC.163 (78), a simplified version of VDR for small vessels with the ability to record only basic data.
Input | VDR | S-VDR |
Date and time | + | + |
Vessel position | + | + |
Speed | + | + |
Header | + | + |
Audio Bridge | + | + |
Audio Communications | + | + |
Radar data | + | + |
AIS - (Radar alternative) | Not necessarily | In the absence of radar signal is available |
Acceleration and hull stresses (if fitted) | + |
Only when they are available on the bridge interface IEC 61162
|
Echo-sounder | + | |
Engine Order and Response | + | |
Hull openings (doors) Status | + | |
Home Alarm (Alarm bridge Mandatory IMO) | + | |
Policies and steering response | + | |
Watertight doors and their status | + | |
Wind speed and direction | + |
High reliability is ensured embedded operating system Linux. HLD-S2 consists of compact units that provide an easy installation on a vessel of any size. Analog and digital signal inputs can be easily adapted to the specific requirements of marine equipment.
Specifications:
- 16 channels NMEA0183/IEC61162, 4800-115200 bit.
- 4 audio channels.
- 9 Microphone Interface,
- 3 standard interface VHF
- 2 VHF custom interface.
- Up to 4 channels video input for Radar, ECDIS, video, etc..
- 5-Port Ethernet 100M for maintenance, loading and other applications.
- 1 channel for an isolated pulse (passive or active, can be customized) for the speed of the journal.
- Input power supply voltage: DC 18-36 V, AC 85-265V, 47-63Hz.
- Output: DC 24 V, max. 10 A.
- Max. Output Power: 300 Watts.
- Battery life Power:> 2h.
- Power Source: 24V/0.2.
- Fault indication and alarm.
- Data backup.
- Microphone Frequency range: 100 ~ 12 kHz.
- Special protective covering of the shell.
- Communication with the main unit: Ethernet.
- Capacity: 2GB.
- Operating system: Embedded Linux with a high degree of reliability and stability.
- Protecting container satisfies the specific requirements of IEC61996.
Additional Information:
TC Transducer Teledyne Transducers Teledyne TS series