ENG
Magnetron MG5028
MG5028 magnetron for linear accelerators, operates in the frequency band 2852 - 2861 MHz with a peak power output of 5500 kW. Magnetron must be protected from the load using the isolator or circulator.
MG5028 magnetron and magnet are built waterproof covers. Magnetron MG502 requires water flow of 18 to 27 L / min; Pressure drop is a maximum of 103 kPa. Electromagnet requires water flow 4.5 l / min at a pressure drop of 14 kPa.
Specifications:
- The maximum anode voltage - 55 kV
- Maximum anode current of -265 A
- Input Power - 7.0 kW
- Pulse duration - 5.0 ms
- The rate of rise of the pulse voltage - 150 kV / m
- Frequency: 2852 - 2861 MHz
- Maximum output power - 500 kW
- Heater Voltage - 6.0
- Weight - 8 kg
Additional Information |
Summary table of magnetrons |
How to replace a magnetron with a radar |
Magnetrons for radar in stock |
Available for order
Documentation:
Installation of a float-free VDR capsule Providing improved data transfer