ENG
M5187F X-Band Magnetron
M5187F X-Band Magnetron with fixed frequency pulse operates at frequencies 9410 ± 30 MHz. This is replacement of magnetron M515 and its equipment is manufactured on the principle of maximum limits in contact with high voltage circuits and all high voltage circuits and terminals are hidden. Equipped with emergency button to turn off the power supply in the event of a device failure.
Specifications:
- The operating frequency - 9410 ± 30 MHz
- Maximum peak power - 25 kW
- Clutch - UG-40B / U
- (NATO 5985-99-083-0051 SN)
- Cooling - natural
- The indirectly heated cathode
- Heater voltage - 6.3 V
- Current heater - 6,3 V - 0,55 A
- Weight - 1.5 kg
- Mounting position - Any
- Minimum gap - 50 mm
- Anode current (peak value) - 6.0 10 A
- Power consumption (peak) - 5.7 kW
- Power consumption (average) - 6.9 W
Additional Information |
Summary table of magnetrons |
How to replace a magnetron with a radar |
Magnetrons for radar in stock |
Available for order
Documentation:
Spare parts for JRC Spare parts for JRC equipment