ENG

DFM 8D

DFM 8D
DFM 8D - is a pulse sensor designed to monitor fuel consumption. Another name is a volumetric differential flowmeter. Provides fuel consumption accounting between forward and reverse flow. With the help of such a sensor, the user is given the opportunity to control, without interfering with the fuel supply system.
 
The sensor readings are subsequently displayed on the LCD eight-bit display. Also, you can additionally submit a testimony on the on-board computer. The throughput of the DFM 8D is 150 liters of flammable liquid per hour. The operating temperature range varies between values from -40 to + 125 ° C. The package includes special adapters, which allow to connect the device to any fuel system. In addition to the basic functions, it is possible to make corrections to the device necessary for measuring fuel in accordance with environmental conditions. Thus, the measurement accuracy of the flow rate reaches 99%.
 
Specifications:
  • The flow of fuel is from 20 to 200 liters per hour,
  • Consumption of fuel - from 4 to 150 liters per hour
  • Permissible pressure - Up to 1.6 MPa
  • The maximum permissible measurement error is ± 1%
  • Internal resistance of the sensor - Up to 13 kPa at 135 l / h
  • Operating temperature - from -40 to + 125 ° С
  • Protection class - IP66
  • Electrical connections - Special cable 6 X 0.75 mm2 (7.5 m included)
Available for order

DFM 8D

to order
Call our sales manager

Worldwide marine radiofacsimile broadcast schedules Worldwide marine radiofacsimile broadcast schedules Worldwide marine radiofacsimile broadcast schedules