ENG
Alarm unit Unicont AU-106 (2 inputs)
Block Unicont AU-106 is designed for a visual and audible alert skipper for the inclusion of an external alarm marine equipment having output for connecting external alarm based on the closing / opening of 'dry' contacts , or by applying a voltage level .
When an external alarm connected to the AU- 106 equipment , the device will emit beeps and blinking LED built into the acknowledgment button . Pressing the alarm acknowledgment buzzer stops. If the alarm is still connected equipment is turned on, the LED built into the button stays on, and not blinking. When you turn off the alarm on the connected equipment, the LED goes out . When restarting the alarm on the connected equipment paging cycle repeats .
Features:
- Power supply: 12 - 24 VDC.
- Voltage levels at the input «U»: 5/12/24/110/220 In
- Current consumption on input «Relay»:> 2 mA
- Current: > 50 mA
- Dimensions : 88 x 108 x 54 (mm)
- Device weight: not more than 500 grams
- Operating Temperature Range: - 20 .. + 60 ° C
- Storage temperature : - 55 .. + 70 ° C
- Protection class : IP 22
Available for order
Documentation: