ENG

Emergency alarm 'AS-2'

Emergency alarm 'AS-2'

Emergency alarm 'AS-2' -  signaling device shipboard systems designed to supply an emergency signals on vessels and platforms under the PPP register and RMRS.

 On the control unit has buttons for automatic feeding signals (eg abandonment) and to signal manually in different lines. also has a lock button keypad and buttons control the brightness of the backlight.

On the back side of the terminal block located AS20:   

- X1 - for connecting cables to the signal 'Signal passengers', 'signal  command ',' Typhon ',' outputs ',' Signal in the voyage data recorder '   on X1 derived in accordance with the wiring diagram alarm systems 
- X2 - to connect cables to the signal 'Disabling broadcast' to the inputs of  an external trigger to control the availability of power outputs on lines warning to connect the power supply cable 24 V power supply (from Pm / ARSCH) derived on  X2 in accordance with the wiring diagram alarm systems 
 
On blocks switching signaling AC-21 AC-24 ... are the following  terminals: 
- X1 - for connecting the power cable; 
- X2 - to connect the cable to the panel signals AC-20: 'Signal passengers',  'command signal' to the output control Power supply lines alert  panel power AC-20. 
- X3 - for external contact 'Lock speakers from HHS,' connecting  lines to alert the crew / passengers. 
- X4 - a manual switch for connecting an emergency supply signals.  1.2.8 On blocks switching power supply AC-25 AC-28 ... are the following terminals: 
- X1 - to connect the power cable of the main and emergency source of  power; 
- X2 - for connecting the external device power supply. 
 
AS-2 performs the following functions: 
- Sounds an alarm to passengers; 
- Feed the signal to the crew; 
- Inclusion of Typhon; 
- Issuance of a signal failure; 
- Issuing signal voyage data recorder; 
- Turn off the broadcast; 
- AS-2 launch from external devices; 
- Availability control voltage on alert. 

Kit:

-  an emergency panel ADF signals AC-20  - Control sound and light signals in emergency situations in automatic and manual modes. Panel AC-20 has a built singalizator and dimmer. Control panel has ports alarms and relay outputs: for signaling Typhon; signaling translation; designation for failure APPSS; data in RDR.

-  switching unit sensors  designed for switching power supply ship sirens and howler monkeys or other light bars, has an entrance lock reference system handsfree (HHS) and the manual feed slot with the Sinhalese remote posts.

-  junction boxes  with fuses to connect sirens, howler monkeys or other sound-devices and indicator lights for general ship an emergency alarm.

-  alarms  designed to alert personnel audible and / or visual alarm.

-  Switching power supply unit  is designed for automatic switching equipment for emergency power failure in the main.

-  power supply  designed to convert AC voltage or DC voltage into a DC voltage 24V.

-  post-button  is designed to supply an emergency signals manually.

 

Notation and main characteristics of the products an emergency alarm

Type of product

Functionality

Executive Board -tion

Number of groups / lines alert

Voltage 
, V

The frequency of 
feeding 
, Hz

Maximum 
switching 
current, A

Private consumption
power, W

Degree of protection

Weight

AC-20

Panel ADF an emergency signal

Remote-BoE

2

= 24

-

3

3

IP44

0.4

AC-21

Switching unit alarms with manual switch signals an emergency supply

by  Din - 
rail

1

= 24

-

10

1.38

IP20

0.8

AC-22

by  Din - 
 
 rail

2

= 24

-

10 10

2.76

IP20

1.1

AC-23

by  Din - 
 
 rail

1

220

50/60

10

2.35

IP20

0.9

AC-24

by  Din - 
rail

2

220

50/60

10 10

4.7

IP20

1.2

AC-25

Power switching unit

by  Din - 
rail

-

= 24

-

10

3.03

IP20

0.62

AC-26

by  Din - 
rail

-

= 24

-

20

8

IP20

0.71

AC-27

by  Din - 
 
 rail

-

220

50/60

10

3.95

IP20

0.62

AS-28

by  Din - 
rail

-

220

50/60

20

8

IP20

0.71

AC-29

Post-button

plastic. 
body

-

300

-

5

-

IP56

0.25

In  the performance of switchboard  equipment kit signaling an emergency kit items (except for junction boxes and sensors) are built in wardrobe, designed for mounting on a bulkhead. 

Available for order

Emergency alarm 'AS-2'

to order
Call our sales manager
Documentation:

Factory acceptance tests Factory acceptance tests Commissioning is the process of fine-tuning the installed equipment so that it works correctly and performs its functions. They are carried out in stages, starting from the manufacturer's workshop, where important equipment is checked before being sent to the shipyard. These checks carried out by the manufacturer are called Factory Acceptance Test (FAT). They confirm that the equipment was in order when it left the shop.