ENG
Multifunctional converters MTR
Multifunctional devices MTR-4 manufactured by DEIF, used on ships, are designed to measure and monitor various electrical values in single-phase or three-phase networks. The wide range of measured parameters (over 50) makes the MTR-4 the ideal choice for a wide variety of applications.
Convenient free software M-SET allows you to customize the data at the user's discretion. The MTR-4 unit is configured via a Windows PC. The converter is connected to the computer using the USB interface. Auxiliary power supply to the transmitter is not required to configure it.
MTR-4 converters are supplied in the following modifications:
Multifunctional measuring transducers MTR-3 are used to measure and monitor the rms values in the AC network. The built-in microcontroller calculates electrical parameters (frequency, power, power factor, THD, phase angles, etc.) based on the measured values (voltage, current).
A special feature of the MTR-3 converter is an additional USB 2.0 interface, which can be used to quickly configure the device without the need to supply power to the device. This interface is not galvanically isolated from the measuring inputs and can only be used with the measuring circuits disconnected.
MTR-3 converters are supplied in the following modifications:
Convenient free software M-SET allows you to customize the data at the user's discretion. The MTR-4 unit is configured via a Windows PC. The converter is connected to the computer using the USB interface. Auxiliary power supply to the transmitter is not required to configure it.
MTR-4 converters are supplied in the following modifications:
- MTR-4-015 without analog outputs with Modbus RS485 interface
- MTR-4-105 one analog output
- MTR-4-215 two analog outputs with Modbus RS485 interface
- MTR-4-315 three analog outputs with Modbus RS485 interface
- MTR-4-415 four analog outputs with Modbus RS485 interface
Multifunctional measuring transducers MTR-3 are used to measure and monitor the rms values in the AC network. The built-in microcontroller calculates electrical parameters (frequency, power, power factor, THD, phase angles, etc.) based on the measured values (voltage, current).
A special feature of the MTR-3 converter is an additional USB 2.0 interface, which can be used to quickly configure the device without the need to supply power to the device. This interface is not galvanically isolated from the measuring inputs and can only be used with the measuring circuits disconnected.
MTR-3 converters are supplied in the following modifications:
- MTR-3-015 without analog outputs with Modbus RS485 interface
- MTR-3F-215 two fast analog outputs with Modbus RS485 interface
- MTR-3F-315 three fast analog outputs with Modbus RS485 interface
- MTR-3F-415 four fast analog outputs with Modbus RS485 interface
- MTR-3-315 three analog outputs with Modbus RS485 interface
- MTR-3-415 four analog outputs with Modbus RS485 interface
- MTR-3 two digital outputs, one analog output and Modbus RS485 interface
Available for order
GMDSS equipment inspection frequency In order for the GMDSS equipment to function properly and efficiently in case of emergency, it is important that seafarers understand its purpose and perform the necessary maintenance on board the vessel in order to maintain it in working condition and make the best use of the GMDSS equipment