ENG
Magnetron M1913S
M1913S is a C-band magnetron which is designed to operate in the frequency range of 5450MHz to 5820MHz with a maximum output of 250 kW. Magnetron M1913S lightweight, robust and compact, constantly monitoring the quality of passes.
The pulses are determined as missing when the magnetron power level is less than 70% of the normal level of energy in the nominal frequency range. Missing pulses are expressed as a percentage of the number of input pulses for the last 3 minutes of the test. These tests are conducted at frequencies F1 = 5450 ± 20 MHz, F2 = 5600 ± 20 MHz, F3 = 5800 ± 20MHz.
Specifications:
- Heater Voltage: 9.5
- Minimum preheating: 300 seconds
- The maximum anode voltage - 29.0 kV
- Maximum anode current - 32 A
- The rate of rise of the pulse voltage - 100 kV / microsecond
- The pulse duration of 0.2 ms
- Maximum power consumption - 928 kW
- Average power consumption - 928 W
- Weight - 24 kg
Ref Min Max Ref Min Max Ref Min Max | |||||||||||||||
A | 210.0 | 230.0 | R | 123.55 124.05 | AJ | 8.4 | |||||||||
B | 58.72 | 65.07 | S | 129.75 130.25 | AK | 98.15 98.65 | |||||||||
C | 57.0 | 58.4 | T | ?8.5 ?8.9 | AL | ?6.5 ?7.5 | |||||||||
E | - | 226.21 | U | - 87.3 | AM | 12 | |||||||||
H | - | 235.45 | V | - 147.3 | AN | 7 | |||||||||
J | - | 131.57 | X | 6 | AP | 5/8-24-NEF-2 | |||||||||
K | - | ?41.66 | AA | 12 | AQ | ?12.3 ?12.9 | |||||||||
L | - | 92.08 | AB | 14 | AU | No10-32-Nf-2 | |||||||||
M | 6.35 | AC | 1.8 | AS | 45° | ||||||||||
N | - | ?74.7 | AE | 22.15 | |||||||||||
P | 49.92 | 53.12 | AG | 47.55 |
Additional Information |
Summary table of magnetrons |
How to replace a magnetron with a radar |
Magnetrons for radar in stock |
Available for order
Documentation:
FMEA (Failure Mode and Effect Analysis) DP notations - DP (AA) and DP (AAA) - must be verified by FMEA. This method is used to determine the consequences of a single malfunction in the motor system and its control system.