ENG
Magnetron MG5241/MG4010 X-Band
Magnetron MG5241/MG4010 X-Band - compact, durable, lightweight. Operates at a frequency of 9410 + 30 MHz, weight 0.7 kg.
The quality of products is constantly monitored by the manufacturer. Magnetrons undergo mandatory testing for compliance with quality standards.
Maximum and minimum absolute values:
It is not required to reduce the channel voltage at any input power value. The maximum slew rate for stable operation depends on the detailed characteristics of the applied pulse and the design of the pulsator.
The quality of products is constantly monitored by the manufacturer. Magnetrons undergo mandatory testing for compliance with quality standards.
Maximum and minimum absolute values:
- Voltage .... - 7 6.9 V
- Starting current ..... - 3.0 A
- Anode voltage ....... - 5.4 6.4 kV
- Anode current ..... - 3.0 6.0 A
- Input power (average) ..... - 70 W
- Duty cycle .....- 0.0025
- Pulse duration ..... - 2.5 ms
- Voltage pulse slew rate ..... - 150 kV / ms
It is not required to reduce the channel voltage at any input power value. The maximum slew rate for stable operation depends on the detailed characteristics of the applied pulse and the design of the pulsator.
Available for order
Documentation:
Spare parts TOKYO KEIKI Catalogue of spare parts production for TOKYOKEIKI compass.