ENG

Battery Capacity Calculator

Battery Capacity Calculator

23.07.2014

Battery Capacity Calculator

Fill in the number of units of your existing equipment and emergency lighting (gray boxes):

Number of units Type of equipment Transmission Obtaining
Requirement
IMO  
in NA 
1/2xTX + RX
Average power consumption during transmission Current consumption. at 24 V DC Average power consumption during production Current consumption. at 24 V DC
  MF / HF 6000 Equipment
6310A - 150W 310W 12.9 60W 2.5 0.00
6320A - 250W 600W 25 60W 2.5 0.00
6350 - 1500W 1000W 41.7 60W 2.5 0.00
A full set of radio telex printer, keyboard and terminal posts 120W 5 22W 1 0.00
   
  6000 VHF Equipment
Sailor 6222A
w / o, 6204 Speaker mic
60W 2.5 6W 0.25 0.00
Sailor 6222A
w. 6204 Speaker mic
84W 3.5 8.4W 0.35 0.00
Sailor 6210/15/16/17 60W 2.5 6W 0.25 0.00
Sailor 6248/49 60W 2.5 6W 0.25 0.00
   
  Inmarsat Mini-C 6000 Equipment
Sailor 6110 GMDSS 30W 1.25 2W 0.09 0.000
6006 Message Terminal 20W 0.85 12W 0.5 0.000
H 1252 Printer 100W 4.1 10W 0.4 0.00
Sailor SSAS 6120 30W 1.25 2W 0.09 0.000
Sailor 6130 LRIT 30W 1.25 2W 0.09 0.000
SIRIUS CONTROL BOX
6130 LRIT
      0.01 0.00
   
 
Emergency Light (emergency lighting)
Emergency Light Enter the emergency lighting power consumption in watts: 1.0 0.00
   
  Optional equipment
6101/6103 Alarm Panel       0.1 0.00
Sailor 6282 AIS     12W 0.5 0.00
Sailor 6004 Control Panel     18W 0.75 0.00
Additional load     0.00
Additional load     0.00
Additional load     0.00
SC 4000 Iridium 25W 1 8W 0.4 0.00
H4122 Iridium SSAS       0.3 0.00
DT 4646/TT-3606E     13W 0.5 0.00
In 1252 H 100W 4.1 10W 0.4 2.45
TT-3000E incl. TT-3616C 35W 1.46 13.8W 0.58 1.31
SSAS TT-3026M 23W 0.96 1.8W 0.08 0.56
RT5022 90W 3.75 15W 0.7 0.000

 

Total consumption: 4.320
Only for lead-acid batteries: 
Required battery power for 1 hour 
(Total consumption. + 50%) 
6,480
Required power battery for 6 hours 
(Total consumption + 20%)
5.184

 


Back to the list