UPS-10 Uninterruptible Power Supply
Description:
The UPS-10 converts the vessel's 230 VAC supply to 24 VDC to provide continuous power to onboard equipment. If the mains supply fails, power is supplied by the built-in backup batteries.
The package includes:
The alarm unit provides audible and visual alarms and allows UPS faults to be acknowledged.
Technical specifications
The UPS-10 converts the vessel's 230 VAC supply to 24 VDC to provide continuous power to onboard equipment. If the mains supply fails, power is supplied by the built-in backup batteries.
The package includes:
- UPS-10 uninterruptible power supply
- Alarm unit
The alarm unit provides audible and visual alarms and allows UPS faults to be acknowledged.
Technical specifications
| Mains input voltage | 230 VAC ±10%, 50 Hz |
| Number of phases | 1 |
| Neutral requirements | Isolated or solidly earthed |
| Power factor at rated current | 0.95 (230 VAC) |
| Minimum load short-circuit power | 240 W |
| Maximum inrush current | 30 A |
| Maximum earth leakage current | 10 mA |
| Rated capacity of built-in batteries | 7 Ah |
| Output voltage during mains operation | 24 VDC ±10% |
| Transfer time to backup power | < 100 ms |
| Minimum output voltage during transfer to backup power | 18 VDC |
| Minimum output voltage during backup battery operation | 20 VDC |
| Rated load current | 10 A |
| Maximum load current | 10.5 A for no more than 10 minutes |
| Rated output power | 240 W |
| Maximum output power | 250 W |
| Number of connected loads | 4 |
| Fault alarm type | Built-in and external audible and visual alarms |
| Storage temperature | −30 °C to +75 °C |
| Operating temperature | +5 °C to +55 °C |
| Ingress protection rating | IP22 |
| Switching and conversion unit dimensions | 421 × 301 × 232 mm |
| Alarm and acknowledgement unit dimensions | 152 × 150 × 53 mm |
| Weight | 13.6 kg |
| Mounting | Wall-mounted |