SEAS Line amplifiers

SEAS Line amplifiers
Available for order

SEAS Line amplifiers

to order
Call our sales manager

The device is designed to amplify television signals and radio signals for subsequent distribution in the network.

SEAS 4020   - Line amplifier for 16 outlets (20dB). It is easy to use and install. No additional accessories are required to install and configure the system. Has excellent protection against electrostatic discharge and surge protection. The device is made in a robust casing made of cast aluminum under pressure, corresponding to protection class IP54.

SEAS Line amplifiers

Features:
- Proven and reliable technology
- Simple and easy installation (see instructions)
- No additional accessories in system setup
- Excellent ESD and Surge protection
- Line amplifier for worldwide marine use
- Sturdy die-cast housing conforming to protection class IP54
- DC blocking on output (req. for replacing other brand active antennas)

Specifications:

  • Size (H) 230 x (W) 165 x (D) 82 mm
  • Housing: Aluminum Die-casting,
  • Finish: Black
  • Connectors IN, OUT: 5/8 "-24 NEF F-Female to 3/8" -32 UNEF F-Female
  • Adapter bush Cord Ø12.5, black:
  • Control relay weight 2.5 kg
  • Output level, 2 signals 105 dBuV, IMD of the third order IMD Change of gain with temperature 0.02 dB / C max. 
  • Manual attenuation FM 40 ~ 110 MHz 0 ~ 20 dB TV 170 ~ 890 MHz 0 ~ 20 dB
  • Current consumption 150 mA +/- 10%
  • Input voltage 230 V AC / 50/60 Hz. Alt 117 VAC ** Current amplifier current max. 200 mA. 
  • Operating temperature -40 to + 60 ° C
  • Disable the built-in relay, activated by a single-pole switch. EMC & Safety EMC EN50083-2, EN61000-3-2 / 3-3
  • Protective earthing **** 1 V AC max. *) At 40 MHz -1.5 dB / oct. **) Alternative fuse included in the box ***). Test using a voltage meter used between the protective earth terminal of the mains plug and all available conductive parts. ****) Test with a Hi-Pot tester.

SEAS 4030   - Line amplifier for 32 outlets (30dB)
SEAS Line amplifiers
Features:
- Proven and reliable technology
- Simple and easy installation
- No additional accessories in system setup
- Excellent ESD and Surge protection
- Line amplifier for worldwide marine use
- Advanced ALC (Automatic Level Control) with LO-HI switch
- Test points on input and output
- Sturdy die-cast housing conforming to protection class IP54
- Equipped with S-band input for cable-TV channels or modulated satellite channels

Specifications:
  • Size (H) 230 x (W) 165 x (D) 82 mm
  • Housing: Aluminum Die Casting,
  • Finish: Black painting
  • Connectors IN,OUT: 5/8”-24 NEF F-Female to 3/8”-32 UNEF F-Female Adapter S-IN: 3/8”-32 UNEF F-Female Connector
  • Control relay weight 2.32 kg
  • Output level, 55/ 550/ 860 MHz. 77 NTSC channels. +312 MHz digital (97 / 102 / 94 dBc V)
  • Power consumption (including antenna output) 16 W, (25 W)
  • Input voltage 230 V AC / 50/60 Hz. Alt 117 VAC
  • Operating temperature -40 to +60°C
  • Deactivation of the built-in relay activated by a single pole switch. EMC & Safety EMC EN50083-2, EN61000-3-2 / 3-3

SEAS 4040  - Line amplifier for 48 outlets (36/44dB)
SEAS Line amplifiers
Features: 
- Digital and Analoque
- Worldwide Marine use
- Proven and reliable technology
- Simple and easy installation
- No additional accessories in system setup
- Excellent ESD and Surge protection
- Line amplifier for worldwide marine use
- Sturdy die-cast housing conforming to protection class IP54
- Advanced ALC (Automatic Level Control) with LO-HI switch

Specifications:
  • Size (H) 265 x (W) 190 x (D) 110 mmHousing: Aluminum Die Casting,
  • Finish: Black painting
  • Connectors: IN: 5/8”-24 NEF F-Female to 3/8”-32 UNEF F-Female Adapter OUT: F-Female Connector (4 pcs)
  • Control relay weight 3.50 kg
  • Output level, 55/ 550/ 862 MHz 77 NTSC channels. +312 MHz digital (97 / 102 / 94 dBc V)
  • Power consumption including power output to antenna 35 W
  • Input voltage 100-230VAC +/-5% / 50/60Hz.
  • Operating temperature -40 to +60°C
  • Deactivation of the built-in relay activated by a single pole switch. EMC & Safety EMC EN50083-2, EN61000-3-2 / 3-3

SEAS 4041 - Line Amplifier for 56/64 outlets (36/44dB) 
SEAS Line amplifiers
Features: 
- Digital and analoque
- Worldwide marine use
- Proven and reliable technology
- Simple and easy installation
- No additional accessories in system setup
- Excellent ESD and surge protection
- Line amplifier for worldwide marine use
- Advanced ALC (Automatic Level Control) with LO-HI switch
- Test points on input and output
- Sturdy die-cast housing conforming to protection class IP54
- Multistandard modulator built in for PAL, SECAM, NTSC

Specifications:
  • Size (H) 265 x (W) 190 x (D) 110 mm
  • Housing: Aluminum Die Casting,
  • Finish: Black painting
  • Connectors IN: 5/8”-24 NEF F-Female to 3/8”-32 UNEF F-Female Adapter OUT: F-Female Connector (4 pcs)
  • Control relay weight 3.50 kg
  • Output level, 55/ 550/ 862 MHz 77 NTSC channels. +312 MHz digital (97 / 102 / 94 dBc V)
  • Power consumption (including antenna power output) 35 W
  • Input voltage 100-230VAC +/-5%/ 50/60Hz
  • Operating temperature -40 to +60°C
  • Deactivation of the built-in relay activated by a single pole switch. EMC & Safety EMC EN50083-2, EN61000-3-2 / 3-3
  • Protective grounding <0.1 ohm

SEAS 4042 - Line Amplifier with Digital Modulatior
SEAS Line amplifiers
Features: 
- Digital and analoque
- Worldwide marine use
- Proven and reliable technology
- Simple and easy installation
- No additional accessories in system setup
- Excellent ESD and surge protection
- Line amplifier for worldwide marine use
- Advanced ALC (Automatic Level Control) with LO-HI switch
- Test points on input and output
- Sturdy die-cast housing conforming to protection class IP54
- Build-in Digital Modulator for DVB-T

Specifications:
  • Size (H) 265 x (W) 190 x (D) 110 mm
  • Housing: Aluminum Die Casting,
  • Finish: Black painting
  • Connectors IN: 5/8”-24 NEF F-Female to 3/8”-32 UNEF F-Female Adapter OUT: F-Female Connector (4 pcs)
  • Control relay weight 3.50 kg
  • Output level, 55/ 550/ 862 MHz 77 NTSC channels. +312 MHz digital (97 / 102 / 94 dBc V)
  • Power consumption including power output to antenna 35 W
  • 100-230VAC +/-5%/ 50/60Hz.
  • Operating temperature -40 to +60°C
  • Deactivation of the built-in relay activated by a single pole switch. EMC & Safety EMC EN50083-2, EN61000-3-2 / 3-3

Catalog GLOMEX 18.04.2016 Catalog GLOMEX
Catalog of equipment and spare parts GLOMEX